Interlabs logo Laboratory Equipments
 

Products by Category

Analytical and Scientific Instruments
Animal Cage
Astronomy
Audio visual item
Biology
Blood Bank Instruments
Centrifuge Wares
Charts
Chemical Electrical Heating Appliances
Chemistry
Civil Engineering Instruments
Compressor & Vaccum Pumps
Consumables
Cryo Labware
Desiccators
Diagnostic products
Digital Blue Products
Digital Controllers
Digital Instruments
Digital Meter & Testers
Digital Scales
Disposable Medical Surgical Products
Education Labs
Educational Aids
Educational Charts
Educational Materials
Electric Actuators
Electrical engineering laboratory
Electronic Educational Equipments
Engineering Equipments
Engineering, Polytechnic and Vocational Training Equipment
Environmental
Equipments For Fluid Mechanics Laboratary
Experimental Training Equipments
Fibre Glass Models
Flats & Wedges
Force & Motion
Forensic Models
Geared Servo Motors
Giant Heart Model
Globes, Maps, 3D Models & Charts
GSM Mobile Communication System Experiment Kit
Hand Tools
Hospital Furniture
Hospital Instruments
Hydraulics
Image Analysis Softwares
Jacketed Reactor
Lab & General Equipment
Laboratory equipment
Laboratory Glassware
Laboratory Instruments
Laboratory Plasticware
Laboratory Supplies
Laboratory Testing Instruments
Laser Trainers
Liquid Handling System
Material Testing Machines
Medical Batteries
Medical consumables
Medical Equipments
Microscopes
Microscopes and Accessories
Microtomes
Motorized Potentiometer
Nautical Instruments
New Products
Oil & Petroleum Testing
Ophthalmic Equipments
Opthalmic & Ent Equipments
Optical Components
Optical Products
Other Products
Paraffin wax dispenser
Passive Night Vision Devices
Pharma Machinery
Physics
Pipettes
Plastic Labware
Pregnancy Models Set For Nursing Training
Prepared Slides
Process Control Instruments
Psychology Lab Equipments
Quality Control Laboratory Equipments
Safety Products
Scientific Lab. Equipments
Silicaware Quartzware
Silicon Tubing & Components
Solar Products
Solenoids
Spatulas
Stepper Motors
Suction Appratus & Unit
Sugar Factory Instrument
Surgical Instruments
Surgical Rubber Products
Test & Measuring Instruments
Water Stills(Glass & Quartz)
Water Treatment Plants
Waveguides
Wooden Lab Products
left spacer
 
CALIBRATION OF AMMETER

Calibrating an Ammeter is a broad statement, because the Ammeter can be AC or DC. The current ranges can be in uA, or mA, or Amp or a few hundred amperes. So there appears to be a wide variety of ranges in current measurement. Since the measurement philosophy is same for any current meter measurement, a DC ammeter is studied for experimental purpose in this experimental setup.

Any moving coil meter is a current meter. Normally it is designed to deflect the needle for 100 or 200?A FSD depending on the coil resistance used in the meter. This resistance can be called as INTERNAL RESISTANCE OF THE METER. However in reality any electrical or electronic circuits do provide much more current than 100 or 200?A in their circuits, typically anywhere between 1mA to a few Amperes. Therefore any current meter that we use in the laboratory do not have this capability. Therefore some extra elements are added to make it appear as though the current meter really reads what we see in the laboratory. Kirchoffs current law will yield better explanation how this is achieved.

Calibrating an ammeter is a two step approach. An ammeter is said, to have been calibrated, if it can be tested for

a) accuracy of the basic meter with 100?A FSD or
b) If it is calibrated and displayed on the scale of the meter, for functional applications, like displaying any other parameter with engineering units like A, RPM, Kg/Cm2 or 0C etc.

In this trainer, all the facilities required to calibrate an Ammeter is attempted. While doing so, the above tasks are studied for experimental purposes.

Specifications:
Analog Ammeter : Moving coil type
Range : 25mA DC FSD
Digital meter : 3-½ digit digital Ammeter
Range : 20mA DC FSD
Input voltage source : 5 V DC Fixed
Load resistor : A continuously variable load resistance in the range of 100 to
5 K Ohms using potentiometer method.
Shunt resistor : 10K Ohm shunt resistor will be supplied.
Power supply : Necessary built-in power supplies operating at 230V AC mains.
Cabinet : An ergonomically designed cabinet

Qty :

 
Related Product
 


3 PHASE AC MACHINE WITH LOADING ARRANGEMENT


SYNCHRONOUS ALTERNATOR


EXPERIMENTS ON TRANSFORMER SINGLE PHASE TRANSFORMER (OPEN CIRCUIT AND SHORT CIRCUIT TEST)


MEASUREMENT STATION


ALTERNATOR


PATCH PANELS

 
 

Newsletter

 
Your Name :
Country :
Your Email ID:
Security Code
 
 
spacer_btm_newsletter

 

More Products

Chemistry
Biology
Physics
Chemical
Engineering Educational Equipment
 
spacer_btm

 

Our Websites

Interlabs-India.com
AmbalaLab.com
Labs-Glassware.com
PlayDigitalBlue.in
School-Science-Supplies
.com
LabScientificEquipments
.com
Ophthalmic-ENT.com
 
spacer_btm

 

 
GoogleBubblegooglestatusInterlabs India
HomeAbout usProductsExhibitionDownloadContact usFeedbackLinks
Copyright © International Biological Laboratories 2008. All Rights Reserved. Contact Us at : info@labscientificequipments.com
Website Design & Website Development Company India VardhmanSoft