Products by Category

Analytical and Scientific Instruments
Animal Cage
Astronomy
Audio visual item
Biology
Blood Bank Instruments
Centrifuge Wares
Chemical Electrical Heating Appliances
Chemistry
Civil Engineering Instruments
Compressor & Vaccum Pumps
Consumables
Cryo Labware
Desiccators
Diagnostic products
Digital Controllers
Digital instruments
Digital Meter & Testers
Digital Scales
Disposable Medical Surgical Products
Educational Aids
Educational Charts
Educational Materials
Electric Actuators
Electrical engineering laboratory
Electronic Educational Equipments
Engineering Equipments
Engineering, Polytechnic and Vocational Training Equipment
Environmental
Equipments For Fluid Mechanics Laboratary
Experimental Training Equipments
Fibre Glass Models
Flats & Wedges
Force & Motion
Geared Servo Motors
Giant Heart Model
Hand Tools
Hospital Furniture
Hospital Instruments
Hydraulics
Image Analysis Softwares
Jacketed Reactor
Lab & General Equipment
Laboratory equipment
Laboratory Glassware
Laboratory Glassware
Laboratory Plasticware
Laboratory Supplies
Laboratory Testing Instruments
Laser Trainers
Liquid Handling System
Medical Batteries
Medical consumables
Medical Equipments
Microscopes
Microscopes and Accessories
Microtomes
Motorized Potentiometer
Nautical Instruments
New Products
Oil & Petroleum Testing
Ophthalmic Equipments
Opthalmic & Ent Equipments
Optical Components
Optical Products
Other Products
Paraffin wax dispenser
Passive Night Vision Devices
Pharma Machinery
Physics
Pipettes
Plastic Labware
Prepared Slides
Process Control Instruments
psychology lab equipments
Quality Control Laboratory Equipments
Safety Products
Scientific Lab. Equipments
Silicaware Quartzware
Silicon Tubing & Components
Solar Products
Solenoids
Spatulas
Stepper Motors
Suction Appratus & Unit
Sugar Factory Instrument
Surgical Instruments
Surgical Rubber Products
Test & Measuring Instruments
Water Stills(Glass & Quartz)
Water Treatment Plants
Waveguides
Wooden Lab. Products
 
Test & Measuring Instruments-> Test Sets For Transformer
[1] 2 [ Next»]
 
OIL TEST SET
Click to Enlarge
OIL TEST SET

?IBL? make Oil Test Set is ideal for testing of Breakdown/withstand test of transformer and circuit breaker oil, in accordance with IS 6792:1992 for oil testing.

Input: 230V + 10%, 50Hz., 1 phase AC.

Selection chart:

Mode of operationTypeMaximum output(In kV)
with center point of H.V.winding grounded
Manually operatedOTMN050S
OTMN060S
OTMN070S
OTMN075S
OTMN080S
OTMN090S
OTMN100S
OTMN120S
50
60
70
75
80
90
100
120

Motor operated

OTMT050S
OTMT060S
OTMT070S
OTMT075S
OTMT080S
OTMT090S
OTMT100S
OTMT120S
50
60
70
75
80
90
100
120
Microcontroller/Microprocessor based Fully AutomaticOTAU050S
OTAU060S
OTAU070S
OTAU075S
OTAU080S
OTAU090S
OTAU100S
OTAU120S
50
60
70
75
80
90
100
120

Capacity: 10mA in the HT side for all sets.

Transformer: H.V. Transformer used in the Test set is cast resin type of graded insulation with center point of H.V. winding grounded.

Protection: Zero start interlocking & door-interlock is to be provided. Snap acting automatic tripping of H.V. circuit in case of overload or breakdown of oil sample under test.

Overvoltage indication (audio & visual) is also incorporated.

Metering: Analog meter for manually & motor operated sets. Digital display for automatic sets.

Test Vessel: As per IS 6792:1992. A gauge is provided along with the cell to adjust the gap.

Features that can be provided at extra cost for manually & motor operated sets:
Capacity other than standard setting, Digital Metering, Stirring arrangement, Mushroom electrode, Cylindrical electrode.


See Enlarge



OIL TEST SET
Click to Enlarge
OIL TEST SET

?IBL? make Oil Test Set is ideal for testing of Breakdown/withstand test of transformer and circuit breaker oil, in accordance with IS 6792:1992 for oil testing.

Input: 230V + 10%, 50Hz., 1 phase AC.

Selection chart:

Mode of operationTypeMaximum output(In kV)
with center point of H.V.winding grounded
Manually operatedOTMN050S
OTMN060S
OTMN070S
OTMN075S
OTMN080S
OTMN090S
OTMN100S
OTMN120S
50
60
70
75
80
90
100
120

Motor operated

OTMT050S
OTMT060S
OTMT070S
OTMT075S
OTMT080S
OTMT090S
OTMT100S
OTMT120S
50
60
70
75
80
90
100
120
Microcontroller/Microprocessor based Fully AutomaticOTAU050S
OTAU060S
OTAU070S
OTAU075S
OTAU080S
OTAU090S
OTAU100S
OTAU120S
50
60
70
75
80
90
100
120

Capacity: 10mA in the HT side for all sets.

Transformer: H.V. Transformer used in the Test set is cast resin type of graded insulation with center point of H.V. winding grounded.

Protection: Zero start interlocking & door-interlock is to be provided. Snap acting automatic tripping of H.V. circuit in case of overload or breakdown of oil sample under test.

Overvoltage indication (audio & visual) is also incorporated.

Metering: Analog meter for manually & motor operated sets. Digital display for automatic sets.

Test Vessel: As per IS 6792:1992. A gauge is provided along with the cell to adjust the gap.

Features that can be provided at extra cost for manually & motor operated sets:
Capacity other than standard setting, Digital Metering, Stirring arrangement, Mushroom electrode, Cylindrical electrode.


See Enlarge



OIL TEST SET
Click to Enlarge
OIL TEST SET

?IBL? make Oil Test Set is ideal for testing of Breakdown/withstand test of transformer and circuit breaker oil, in accordance with IS 6792:1992 for oil testing.

Input: 230V + 10%, 50Hz., 1 phase AC.

Selection chart:

Mode of operationTypeMaximum output(In kV)
with center point of H.V.winding grounded
Manually operatedOTMN050S
OTMN060S
OTMN070S
OTMN075S
OTMN080S
OTMN090S
OTMN100S
OTMN120S
50
60
70
75
80
90
100
120

Motor operated

OTMT050S
OTMT060S
OTMT070S
OTMT075S
OTMT080S
OTMT090S
OTMT100S
OTMT120S
50
60
70
75
80
90
100
120
Microcontroller/Microprocessor based Fully AutomaticOTAU050S
OTAU060S
OTAU070S
OTAU075S
OTAU080S
OTAU090S
OTAU100S
OTAU120S
50
60
70
75
80
90
100
120

Capacity: 10mA in the HT side for all sets.

Transformer: H.V. Transformer used in the Test set is cast resin type of graded insulation with center point of H.V. winding grounded.

Protection: Zero start interlocking & door-interlock is to be provided. Snap acting automatic tripping of H.V. circuit in case of overload or breakdown of oil sample under test.

Overvoltage indication (audio & visual) is also incorporated.

Metering: Analog meter for manually & motor operated sets. Digital display for automatic sets.

Test Vessel: As per IS 6792:1992. A gauge is provided along with the cell to adjust the gap.

Features that can be provided at extra cost for manually & motor operated sets:
Capacity other than standard setting, Digital Metering, Stirring arrangement, Mushroom electrode, Cylindrical electrode.


See Enlarge



OIL TEST SET
Click to Enlarge
OIL TEST SET

?IBL? make Oil Test Set is ideal for testing of Breakdown/withstand test of transformer and circuit breaker oil, in accordance with IS 6792:1992 for oil testing.

Input: 230V + 10%, 50Hz., 1 phase AC.

Selection chart:

Mode of operationTypeMaximum output(In kV)
with center point of H.V.winding grounded
Manually operatedOTMN050S
OTMN060S
OTMN070S
OTMN075S
OTMN080S
OTMN090S
OTMN100S
OTMN120S
50
60
70
75
80
90
100
120

Motor operated

OTMT050S
OTMT060S
OTMT070S
OTMT075S
OTMT080S
OTMT090S
OTMT100S
OTMT120S
50
60
70
75
80
90
100
120
Microcontroller/Microprocessor based Fully AutomaticOTAU050S
OTAU060S
OTAU070S
OTAU075S
OTAU080S
OTAU090S
OTAU100S
OTAU120S
50
60
70
75
80
90
100
120

Capacity: 10mA in the HT side for all sets.

Transformer: H.V. Transformer used in the Test set is cast resin type of graded insulation with center point of H.V. winding grounded.

Protection: Zero start interlocking & door-interlock is to be provided. Snap acting automatic tripping of H.V. circuit in case of overload or breakdown of oil sample under test.

Overvoltage indication (audio & visual) is also incorporated.

Metering: Analog meter for manually & motor operated sets. Digital display for automatic sets.

Test Vessel: As per IS 6792:1992. A gauge is provided along with the cell to adjust the gap.

Features that can be provided at extra cost for manually & motor operated sets:
Capacity other than standard setting, Digital Metering, Stirring arrangement, Mushroom electrode, Cylindrical electrode.


See Enlarge



OIL TEST SET
Click to Enlarge
OIL TEST SET

?IBL? make Oil Test Set is ideal for testing of Breakdown/withstand test of transformer and circuit breaker oil, in accordance with IS 6792:1992 for oil testing.

Input: 230V + 10%, 50Hz., 1 phase AC.

Selection chart:

Mode of operationTypeMaximum output(In kV)
with center point of H.V.winding grounded
Manually operatedOTMN050S
OTMN060S
OTMN070S
OTMN075S
OTMN080S
OTMN090S
OTMN100S
OTMN120S
50
60
70
75
80
90
100
120

Motor operated

OTMT050S
OTMT060S
OTMT070S
OTMT075S
OTMT080S
OTMT090S
OTMT100S
OTMT120S
50
60
70
75
80
90
100
120
Microcontroller/Microprocessor based Fully AutomaticOTAU050S
OTAU060S
OTAU070S
OTAU075S
OTAU080S
OTAU090S
OTAU100S
OTAU120S
50
60
70
75
80
90
100
120

Capacity: 10mA in the HT side for all sets.

Transformer: H.V. Transformer used in the Test set is cast resin type of graded insulation with center point of H.V. winding grounded.

Protection: Zero start interlocking & door-interlock is to be provided. Snap acting automatic tripping of H.V. circuit in case of overload or breakdown of oil sample under test.

Overvoltage indication (audio & visual) is also incorporated.

Metering: Analog meter for manually & motor operated sets. Digital display for automatic sets.

Test Vessel: As per IS 6792:1992. A gauge is provided along with the cell to adjust the gap.

Features that can be provided at extra cost for manually & motor operated sets:
Capacity other than standard setting, Digital Metering, Stirring arrangement, Mushroom electrode, Cylindrical electrode.


See Enlarge



TRANSFORMER TURNS RATIO METER
Click to Enlarge
TRANSFORMER TURNS RATIO METER

Transformer Turns Ratio Meter is compact in size and is capable to measure actual turns ratio of different types of transformers like Distribution, Power, CT, PT, Auto-transformers, Control & Measuring transformers etc.

FEATURES:

  • Suitable to measure percentage ratio error directly.
  • Polarity indication by phase sensitive null detector.
  • Additional 3 phase switch network for Type TTR1P3, TTR10P3 & TTR20P3.
  • Direct ratio error measurement range + 1% of the range with resolution of 0.05 %.
  • Direct ratio error measurement accuracy + 0.25% of the reading.
  • Null indicator: Center zero microampere meter fed through electronic null detector.
  • Digital meter may be provided at extra cost.
  • Over load / Short circuit & HT/ LT reversal protection.
  • Power supply input: 230 volts ? 10%, single phase, 50 Hz. AC.

See Enlarge



DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
Click to Enlarge
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET

This test set provides a continuously variable output voltage at double frequency to test the insulation between turns of coils, layer to layer, terminals of windings with either uniform or graded insulation and also between the windings and earth, with graded insulation of both Distribution and Power transformers.
An alternating voltage of sine wave form (as much as possible) at double frequency (100 Hz.) and double in amplitude can be applied at one side of the transformer under test while the windings, which are not connected to the source of excitation, are left on open circuit. This higher frequency is considered to avoid excessive excitation current during the testing.

Voltage source:

To generate a voltage at 100 Hz., one 3-phase squirrel cage induction motor is given a supply through a star-delta switch. This motor drives the slip ring induction motor (generator). A variable voltage is also supplied to the generator thereby producing double frequency, which along with the output voltage of the generator is available across the terminals of the Set.

Selection chart:

Type

Output capacity of generator(slip-ring motor)

In HP

Output capacity of generator(slip-ring motor)

In kW

Suitable to test transformer upto
dfdv010h 10HP 7.5KW250KVA
dfdv020h 20HP15 KW 750KVA
dfdv025h 25HP18.75KW1MVA
dfdv030h 30HP22.5KW 2MVA
dfdv040h 40HP30KW 3MVA
dfdv050h 50HP37.5KW 4MVA

dfdv060h

60HP 45KW 5MVA
dfdv080h 80HP 60KW6MVA
dfdv100H 100HP 75KW 7.5MVA
dfdv150h 150HP112.5KW 11.2MVA

See Enlarge



AC HIGH VOLTAGE TEST SET
Click to Enlarge
AC HIGH VOLTAGE TEST SET

IBL" make High voltage testing sets are suitable for Power frequency AC high voltage test on transformers, motors, insulators, cables etc. The sets are capable of giving continuously variable AC HIGH VOLTAGE from zero to maximum rated output voltage.

Input: Generally, 230 Volts, 50Hz, single phase AC, upto 10KVA & 400/415V, two phase out of three
phases for sets beyond 10KVA.
However, we also manufacture AC H.V. sets workable on other input voltage at extra cost.

Output: Continuously variable from zero to maximum rated output voltage.

Capacity: Spread over a wide range of sets from 2.5KV to 300KV AC having capacities from several VA to hundreds of KVA.
Duty cycle: Intermittent i.e., 5 minutes ON, 10 minutes OFF. However, test sets of continuous or other duty cycles can also be manufactured at extra cost.

Metering: Analog voltmeter & milliammeter/ammeter. Digital meters may be provided at extra cost.

Protection: Tripping mechanism for protecting the H.V. transformer against over loading. The tripping mechanism can be adjusted at 25,50 & 100% of the rated current by a rotary switch. Below 100mA &
above 20mA two adjustable tripping ranges are at 50% &100%, while for sets of 20mA capacity or below only 100% is adjustable [If required by the users tripping current can be made adjustable at other values, at extra cost].
Apart from tripping mechanism, Zero start interlocking along with Overvoltage alarm & indication are provided.

Mode of operation: Sets are generally, motor operated beyond 20KVA & 50KV. Motorisation facility can be available below the specified value at extra cost.

H.V Transformer:
H.V.Transformer used for the testing purpose can be oil cooled indoor type or Resin cast dry type as found suitable or particularly required by the customer. The H.V. winding of the high voltage testing transformers is of graded insulation, one end of which is grounded through milliammeter and tripping device while the other end remains in floating condition as H.V. terminal. These testing transformers are specially designed to withstand frequent intermittent spark over or momentary short circuit conditions under which such testing
transformers are supposed to operate.

Discharge Rod: For device under tests having large capacitance, discharge rod may be provided at an extra cost.

While sending enquiry for quotation or order please specify the following:
Input voltage and frequency.
Maximum output voltage.
Capacity.
Type of transformer –Oil cooled or Cast Resin
Duty Cycle.
Mode of operation: Manual/Motor operated.
Any other details you find important to be specified.


See Enlarge



AC HIGH VOLTAGE TEST SET
Click to Enlarge
AC HIGH VOLTAGE TEST SET

IBL" make High voltage testing sets are suitable for Power frequency AC high voltage test on transformers, motors, insulators, cables etc. The sets are capable of giving continuously variable AC HIGH VOLTAGE from zero to maximum rated output voltage.

Input: Generally, 230 Volts, 50Hz, single phase AC, upto 10KVA & 400/415V, two phase out of three
phases for sets beyond 10KVA.
However, we also manufacture AC H.V. sets workable on other input voltage at extra cost.

Output: Continuously variable from zero to maximum rated output voltage.

Capacity: Spread over a wide range of sets from 2.5KV to 300KV AC having capacities from several VA to hundreds of KVA.
Duty cycle: Intermittent i.e., 5 minutes ON, 10 minutes OFF. However, test sets of continuous or other duty cycles can also be manufactured at extra cost.

Metering: Analog voltmeter & milliammeter/ammeter. Digital meters may be provided at extra cost.

Protection: Tripping mechanism for protecting the H.V. transformer against over loading. The tripping mechanism can be adjusted at 25,50 & 100% of the rated current by a rotary switch. Below 100mA &
above 20mA two adjustable tripping ranges are at 50% &100%, while for sets of 20mA capacity or below only 100% is adjustable [If required by the users tripping current can be made adjustable at other values, at extra cost].
Apart from tripping mechanism, Zero start interlocking along with Overvoltage alarm & indication are provided.

Mode of operation: Sets are generally, motor operated beyond 20KVA & 50KV. Motorisation facility can be available below the specified value at extra cost.

H.V Transformer:
H.V.Transformer used for the testing purpose can be oil cooled indoor type or Resin cast dry type as found suitable or particularly required by the customer. The H.V. winding of the high voltage testing transformers is of graded insulation, one end of which is grounded through milliammeter and tripping device while the other end remains in floating condition as H.V. terminal. These testing transformers are specially designed to withstand frequent intermittent spark over or momentary short circuit conditions under which such testing
transformers are supposed to operate.

Discharge Rod: For device under tests having large capacitance, discharge rod may be provided at an extra cost.

While sending enquiry for quotation or order please specify the following:
Input voltage and frequency.
Maximum output voltage.
Capacity.
Type of transformer ?Oil cooled or Cast Resin
Duty Cycle.
Mode of operation: Manual/Motor operated.
Any other details you find important to be specified.


See Enlarge



TRANSFORMER WINDING RESISTANCE METER
Click to Enlarge
TRANSFORMER WINDING RESISTANCE METER

This Test set is suitable to measure winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent displays read the resistance of both primary & secondary windings simultaneously. However, primary or secondary winding can also be measured separately.
DC Power source allows the selected current to flow through the winding /windings and the voltage developed across the winding are sent to instrumentation amplifiers, thereby displaying directly the ohmic value.

Technical Features:

Resistance RangeResistance meter reading displayResolution

Test Current

TypeUONT005A

Test Current

TypeUONT010A

2mW 19.99x0.1 1mW 5A 10A
20mW 19.99x1 10mW 5A 10A
20mW 199.9x0.1 10mW 500mA 1A
200mW 199.9x1 100mW 500mA 1A
0.200W 1999x0.1 100mW 50mA 100mA
2W 1999x1 1mW 50mA 100mA
2W 19.99x0.1 1mW 5mA 10mA
20W 19.99x1 10mW 5mA 10mA
20W 199.9x0.1 10mW 0.5mA 1mA
200W 199.9x1 100mW 0.5mA 1mA
200W 1999x0.1 100mW 0.05mA 0.1mA
2KW 1999x1 1W 0.05mA 0.1mA

Input Power Supply: 230V +10%, single phase, 50Hz. AC.
Accuracy: +1% of selected resistance range.
Display: 2 nos., 31/2 digit LED module for resistance measurement.

Protection:

  • Protection against current lead disconnection while in use, Induction Kickback suppression, Snap acting overload protection.

See Enlarge




[1] 2 [ Next»]