Product Features
- Complete Training System to study the Solar-Hydrogen cycle
- Reversible Fuel Cell-both as an Electrolyzer and as a Fuel Cell
- Measurement and Application Modes
- Weather proof Solar Panel
- Portable and light weight
- Online product tutorial
Technical Specificaions
Solar Panel
Voltage
(at optimum power point) : 2.2V DC
Current
(at maximum power point) : 450mA
Dimensions (mm) : W 125 x D 155 x H 8
Note: Solar Panel data is based on standard conditions
2 0
(1000W/m , 25 C)
Electrolyzer Function
Input Voltage : 1.8~2.6V DC
Input Current : 0.7A
Hydrogen Production Rate : 7ml / min at 1A
Oxygen Production Rate : 3.5ml / min at 1A
Fuel Cell Function
Output Voltage : 0.9V DC
Output Current : 360mA