Capacity Control Methods In Refrigeration

This unit demonstrates several possible ways of regulating the capacity. The cooling capacity of the system with 2 separate evaporators can be changed by adjusting the speed of the open compressor. The compressor drive motor is controlled using a frequency converter. The evaporators are in individual insulated compartments. In the first compartment the temperature is regulated using an intake pressure controller and thermostat (mechanical regulation), in the second compartment using a case controller (electronic regulation). In both cooling compartments a cooling load can be generated using an electrical heater. Fans ensure even temperature distribution. A bypass capacity regulator is installed in the refrigerant circuit that connects the high and low pressure sides of the compressor. The system is equipped with temperature sensors at all relevant measuring points. The signals provided by these sensors are also used by the case controller.

SKU: 719748f97b88 Category:

Capacity Control Methods In Refrigeration

Interlabs presents Capacity Control Methods In Refrigeration, listed under our Refrigeration and Air Condition range. This product page brings together the available product information to help laboratories, educational institutions, engineering departments and procurement teams assess its relevance.

Product Overview

This unit demonstrates several possible ways of regulating the capacity. The cooling capacity of the system with 2 separate evaporators can be changed by adjusting the speed of the open compressor. The compressor drive motor is controlled using a frequency converter. The evaporators are in individual insulated compartments. In the first compartment the temperature is regulated using an intake pressure controller and thermostat (mechanical regulation), in the second compartment using a case controller (electronic regulation). In both cooling compartments a cooling load can be generated using an electrical heater. Fans ensure even temperature distribution. A bypass capacity regulator is installed in the refrigerant circuit that connects the high and low pressure sides of the compressor. The system is equipped with temperature sensors at all relevant measuring points. The signals provided by these sensors are also used by the case controller.

Key Information and Features

The details below are based on the supplied product description. Please confirm the final configuration, included accessories, materials, dimensions and operating requirements with Interlabs before placing an order.

Applications and Use

Capacity Control Methods In Refrigeration is listed in the Refrigeration and Air Condition category. Its intended use should be assessed against the experiments, demonstrations, training activities or operational requirements described in the product information. Contact Interlabs if you need help matching the product to a particular application.

Selection and Enquiry Guidance

When evaluating this product, share your application, required configuration, quantity and any institutional or project requirements. Interlabs can help clarify available options and confirm the product details relevant to your enquiry.

Frequently Asked Questions

What category does this product belong to?

This product is listed under Refrigeration and Air Condition.

Where can I get confirmed specifications?

Contact Interlabs with the product name and your requirements to confirm current specifications, configuration and included components.

Can I request product or bulk enquiry support?

Yes. Share the required quantity, application and delivery location with Interlabs for enquiry assistance.

Contact Interlabs

For product details, technical clarification, configuration questions or a quotation, contact Interlabs and mention Capacity Control Methods In Refrigeration.

Scroll to Top