Infant Care
Showing all 5 results
-
Infant Care
Baby Bassenet (General)
With head down position from both sides, IV stand and large shelf for placing monitors etc.
-
Infant Care
Digi Dopp
Table top
Rust proof
ABS Plastic moulded
Rechargeable battery
Mains operated as well
Bright LED Display to Indicate the Beats per minimum
(BPM) and the digital display of volume level
FHR with HI/Low limit setting
Audio Visual alarm -
Infant Care
Phototherapy Unit Double Surface
In the new born period i.e birth to one month, jaundice can pose a serious problem, because high level of the billirubin can permanently damage the brain. This indirect billirubin, which is not water soluble, can be decomposed to a harmless metabolic, which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate. This is achieved by exposing the infant to bright light (app. 4.5 micro watts/sq.cm/nm) in the range of 420 to 480nm wave length. This is used for treatment of Hyperbillirubiaemia in Neonates, which provides the light source in range of 420-480 nm wave length. Double surface Phototherapy Unit is the combination of over head phototherapy unit and under Surface Phototherapy unit.
-
Infant Care
Phototherapy Unit Single Surface (Overhead Unit)
Overhead Phototherapy Unit Choice of two kinds of tubes for use with
4 nos. of blue light tubes with higher intensity of light in therapeutic range and 2 nos. of white light tubes.
6 nos. of white light tubes with the facility to use 4 or 6 tubes at a time
Facility of height adjustment, so as to fit over an incubator or baby cot etc.
Fold up facility during inspection of neonates or storage.
Angle folding facility, for using along with radiant warmer.
Compact & mobile -
Infant Care
Tiana C-PAP / Resto Health
The gas delivered by Restohealth contains up to 55 mg/H2O per Liter (depending upon the temperature setting). Clinical studies have proven that high water vapour is effective in mobilizing thickened airway secretions.
Breathing warm & humidified gases from Restohealth is an effective method of Core rewarming especially post surgery or after cold exposure.
Warm humid gases have been found to inhibit the nasal response to allergy. Water vapour at 410 C is as effective as aerosol therapy in reducing allergic rhinitis symptoms.
Restohealth can deliver high flows of warm & humid gases via nasal Cannula which greatly improves patient’s comfort as compared to gases delivered via face mask.
The effect of heat & humidity optimize the use of nasal Cannula thus helps the Practitioner to use higher flows which other wise is not possible.