Laboratory Apparatus

Showing 1–12 of 16 results

  • Energy Hand Gap Apparatus
    Laboratory Apparatus

    Energy Hand Gap Apparatus

    Demonstrates Spark Discharge: Specifically designed to demonstrate electric spark generation and energy transfer across an adjustable air gap.Adjustable Electrode Gap: Features movable metal spheres or rods to vary the spark gap distance for controlled discharge.High Voltage Operation: Works with induction coil or high voltage power source to generate visible sparks.

  • Fet Characteristics Apparatus
    Laboratory Apparatus

    Fet Characteristics Apparatus

    Complete Testing Setup: Designed to study the input and output characteristics of Field Effect Transistors (FETs) in common source configuration.Built-in Regulated Power Supply: Provides stable DC biasing voltages required for accurate FET operation and measurements.Analog Meters: Includes voltmeters and ammeters (analog or digital) for precise measurement of gate, drain, and source parameters.

  • Galvanometer Into Ammeter Conversion Apparatus Kit
    Laboratory Apparatus

    Galvanometer Into Ammeter Conversion Apparatus Kit

    Educational Demonstration Kit: Specifically designed to demonstrate how a sensitive galvanometer can be converted into an ammeter using a shunt resistor.Mounted Galvanometer: Includes a high-quality, low-resistance galvanometer pre-mounted on the panel.Shunt Resistor Included: Comes with a precision low-value shunt resistor to allow high current flow while protecting the galvanometer.

  • Kirchoffs Law Apparatus Kit
    Laboratory Apparatus

    Kirchoffs Law Apparatus Kit

    Pre-Mounted Resistors: Comes with precision resistors already fixed on the board, ensuring consistent and repeatable results.Clear Circuit Layout: Includes a printed or color-coded wiring diagram for easy understanding and setup of experiments.Multiple Circuit Configurations: Supports single-loop and multi-loop networks, enabling a range of practical applications of Kirchhoff’s laws.

  • LCR Impedance Apparatus
    Laboratory Apparatus

    LCR Impedance Apparatus

    Built-in AC Signal Source: Provides a variable-frequency AC power supply suitable for observing frequency-dependent behavior.High-Precision Components: Includes accurately rated inductor, capacitor, and resistor for reliable measurements and consistent results.Analog Meters: Equipped with voltmeter and ammeter to measure voltage, current, and calculate impedance and phase angle.

  • Ldr Characteristics Apparatus
    Laboratory Apparatus

    Ldr Characteristics Apparatus

    Complete Experimental Setup: Designed to study the variation of resistance of a Light Dependent Resistor (LDR) with changing light intensity.Built-in Regulated Power Supply: Provides a stable DC voltage for accurate and reliable measurements.High-Quality LDR Mounted: Light-dependent resistor is securely mounted with easy access terminals for safe and convenient connections.

  • Meldes Experiments Apparatus
    Laboratory Apparatus

    Meldes Experiments Apparatus

    Purpose-Built Design: Specifically designed to demonstrate the formation of stationary waves in a stretched string using mechanical or electromagnetic vibration.
    Sturdy Base Stand: Mounted on a strong base with support rod to ensure stability during vibration.
    Vibrator Unit: Includes a mechanical or electromagnetic vibrator (solenoid type) for generating oscillations.

  • Ohms Law Apparatus
    Laboratory Apparatus

    Ohms Law Apparatus

    Complete Experimental Setup: Designed to verify Ohm’s Law by demonstrating the relationship between voltage, current, and resistance.Built-in Power Supply: Provides a stable DC voltage source for consistent and accurate readings.Analog Meters: Equipped with voltmeter and ammeter (analog or digital) to measure current and voltage precisely.

  • PN Junction Diode Semi Conductor Diode Characteristics Apparatus
    Laboratory Apparatus

    PN Junction Diode Semi Conductor Diode Characteristics Apparatus

    Complete Experimental Setup: Designed to study the V-I characteristics of a PN junction diode in both forward and reverse bias modes. Built-in
    Power Supply: Equipped with regulated DC power source for stable voltage and current control.
    Analog Meters: Includes accurate voltmeter and ammeter (analog or digital) for real-time measurement of current and voltage.

  • Resistance Series Parallel Apparatus
    Laboratory Apparatus

    Resistance Series Parallel Apparatus

    Dual Configuration Study: Enables easy demonstration of both series and parallel combinations of resistances.Mounted Resistors: High-quality resistors are securely fixed with proper terminals for safe and accurate connections.Clearly Marked Connections: All terminals and paths are clearly labeled to simplify wiring and understanding.

  • Rising Table Apparatus
    Laboratory Apparatus

    Rising Table Apparatus

    Demonstrates Friction Laws: Specifically designed for studying and demonstrating the laws of limiting friction on inclined planes.
    Adjustable Inclination: Features a smooth, mechanically adjustable table surface that can be raised or lowered to vary the angle of inclination.
    Graduated Scale or Protractor: Equipped with an angular scale or protractor to measure the inclination angle precisely.

  • Series Parallel Experiment Apparatus
    Laboratory Apparatus

    Series Parallel Experiment Apparatus

    Dual Configuration Study: Designed to demonstrate both series and parallel combinations of resistors in a single setup.Mounted Resistor Network: Includes multiple precision resistors securely fixed on the panel with clearly marked values.Labeled Terminals: Easy-to-identify connection points for series, parallel, and mixed configurations.

Scroll to Top